Description
Performing spirometry tests, in any environment, could not be easier than with the new Micro Direct In2itive spirometer. Simply enter the patient’s details on the color touch-screen display, select FVC or VC and begin the test series.
Test information is presented in an easy to read format on a clear, bright color display. The best test is automatically selected and built-in quality control checks insure accurate results. Test data along with the diagnostic interpretation and estimated lung age can be instantly printed via an external printer or downloaded to the included Spirotrac PC software for permanent storage and trend analysis.
The in2itive features a highly accurate Fleisch pneumotach flow measuring system, battery operated portability and is shipped complete with all necessary accessories in a robust carrying case.
The easy to use and affordable In2itive spirometer provides a fast, accurate and cost effective spirometry solution.
Features | ||
|
Technical Specifications |
Subjects: Automatic population of database from Spirotrac. Name, ID, Age, Height, Gender, Smoking Status, Body Mass Index and more depending on model. Storage of up to 10,000 subjects Environmental Data: Selectable; Temperature (built in sensors), Barometric Pressure, Altitude, Humidity Test Types: Single breath tests, flow/volume loops, multi-breath testing, tidal breathing and combined VC/FVC type test methods supported Parameters Measured (depending on model): VC, IVC, IC, VT (TV), TLC, RV, IRV, ERV, FRC, FVC, FIVC, FEV1, FEV3, FEV6, FEV1/VC, FEV1/FVC, FEV3/VC, FEV3/FVC, EV1/FEV6, FEF75, FEF50, FEF25, FEF25-75, FEF25-75/FVC, FIV1, PIF, FIV1/FIVC, FIF25, FIF50, FIF75, FEF50/FIF50, FET, MVVind, FEV1 Ratio, FEV0.5, PEF L/min, PEF L/sec, FEF 0.2-1.2, FEF75-85%, FEF25%, FEF50%, FEF75%, FMFT, FIF25%, FIF50%, FIF75%, PIF, FEV0.75, Lung Age and more Predicted Normals: NHANES III, Polgar, Knudson, Crapo, Hsu and many more Suggested Interpretation: User Selectable Flow Technology: Fleisch Pneumotachograph Resolution: 10 mL volume; 0.01 L/s flow Data Storage: Stores up to 10,000 subjects and hundreds of test sessions Accuracy when in Operating Range: Volumes: Better than +/- 3% (0 – 10 L) Flows: Better than +/- 10% (0.02 – 16 L/sec) Linearity: +/- 5% in range 0.1 to 16 L/s PowerSAFE TM: Input 100 – 240V AC 50-60Hz Output – 5V DC Battery Pack: Rechargeable Lithium Polymer Dimensions: 6 1/4” x 4” x 1 3/4” with flowhead attached Weight: 8 ounces net Weight and Dimensions (Packed): 3 pounds 5 ounces 8 1/2” x 4” x 6 1/4” Storage Humidity: 10% to 95% Storage Temperature: 32-122oF Recommended Operating Range: 63-98oF; Design Limits: 50 – 104oF Ambient Humidity: 0% to 99% Connectivity: USB 2 Max Test Duration: 20 sec. FVC; 30 sec. VC Performance Standards: ATS/ERS 2005 Safety Standards: IEC 60601-1:2005 Medical Safety Standards: Medical Devices Directive 2007/47/EC Designed & Manufactured Under: ISO 13485:2003, FDA 21CFR820 CMDR & JPAL |